<title>{"english":"DC7 Black building test"}</title>
<link>status/30/--english---dc7-black-building-test--/</link>
<guid>status/30/--english---dc7-black-building-test--/</guid>
<pubDate>Mon, 09 Mar 2026 00:00:00 +0000</pubDate>
<description><![CDATA[{"english":"DC7 \u2013 Manchester \u2013 Black building Test \r\nAs part of our commitment to quality and continual improvement, iomart will be \r\nconducting a Black Building test. The proposed activity will be conducted on the 17th\r\nMarch 2026 and this work is required to ensure that the power back up systems are \r\noperating correctly and to carry out dynamic and functional testing of the switchgear \r\nbreakers to confirm operation. \r\nWhat will happen? \r\nThere will be a series of checks and inspections completed by the combined \r\npersonnel carrying out the work: \r\n\uf0b7 Prior to commencement of work, all systems will be checked and serviced to \r\nmake sure they are running correctly, with no issues \r\n\uf0b7 Mains power to the site will be isolated by Opening the Main Incomer breaker \r\n\uf0b7 Site infrastructure will then go through the process of transferring site load onto \r\nthe standby generator \r\n\uf0b7 IT Load will be maintained throughout this process, as it will be supported by \r\nUPS battery back up \r\n\uf0b7 The site load will be maintained on the generator supply for approximately 60 \r\nminutes, then we will revert back to mains power \r\n\uf0b7 Once testing has concluded, the mains power supply will be re-instated and site \r\ninfrastructure will revert to mains power in normal configuration \r\n\uf0b7 A full site check will be carried out to identify any issues that may have occurred \r\nduring the planned tasks \r\nFollowing reinstatement to normal operation, the combined team will carry out plant \r\nchecks to ensure there are no alarms present and that all systems are operating as \r\nnormal. \r\nWhen will the work be carried out? \r\nThe work will be carried out on the17 March 2026, between 0900 to 1300hrs, \r\nhowever, the expected duration of this activity is approximately 1 hour. \r\nWho will be completing the work? \r\nThe work will be supervised by the iomart Management team who will be monitoring \r\nthe UPS, AC and generator systems. Our specialist contractors \u201cMajas\u201d and \r\nCharmeldon will also be supporting this activity. \r\nWill I experience downtime? \r\nAs with any type of maintenance there is a risk of downtime, however, the Black \r\nBuilding Test is expected to be a Non-Service affecting test. If at any point the risk to \r\nthe site has increased, then the test will be aborted and Mains Power re-instated. \r\n"}]]></description>
</item>
</channel>
</rss>